David T. Harvey is a Professor Emeritus of Chemistry and Biochemistry at DePauw University in Greencastle, Indiana, where he has been a dedicated faculty member since 1986. Over his nearly four-decade career, Dr. Harvey has established himself as a leading voice in analytical chemistry education, renowned for his commitment to making high-quality learning resources accessible to students worldwide.

Contributions

284 resources
Exchange Resource

Peristaltic Pump

A propelling unit moves the carrier stream through the flow injection analyzer. Although several different propelling units have been used, the most…

View Resource →
Exchange Resource

Fiagrams

An FIA curve, or fiagram, is a plot of the detector’s signal as a function of time. The illustration below shows a…

View Resource →
Exchange Resource

Lineweaver-Burk Plots

For an enzyme–substrate reaction following a simple mechanism E + S ↔ E–S ↔ E + P consisting of the initial formation of an enzyme–substrate…

View Resource →
Exchange Resource

Enzyme Kinetics

Enzymes are highly specific catalysts for biochemical reactions, with each enzyme showing a selectivity for a single reactant, or substrate. For example,…

View Resource →
Exchange Resource

Ion-Exchange Chromatography

In ion-exchange chromatography (IEC) the stationary phase is a cross-linked polymer resin, usually divinylbenzene cross-linked polystyrene, with covalently attached ionic functional groups.…

View Resource →
Exchange Resource

LC-MS Detection

The figure below provides a block diagram of a typical liquid chromatography-mass spectrometer (LS–MS) instrument. As illustrated here, a three component mixture is injected…

View Resource →
Exchange Resource

HPLC Pumps

A typical HPLC includes between 1–4 reservoirs for mobile phase solvents. The mobile phase solvents are pulled from their reservoirs by the action…

View Resource →
Exchange Resource

HPLC Column

The most common type of HPLC column is a stainless steel tube with an internal diameter between 2.1 mm and 4.6 mm…

View Resource →
Exchange Resource

GC-MS

The figure below provides a block diagram of a typical gas chromatography-mass spectrometer (GC–MS) instrument. As illustrated here, a three component mixture enters the…

View Resource →
Exchange Resource

GC Injectors

Shown here is a schematic diagram of a heated GC injector port for use with packed columns. The needle from the syringe…

View Resource →
Exchange Resource

GC Syringe

Shown here is an example of a syringe for injecting samples into a gas chromatograph. This syringe has a maximum capacity of…

View Resource →
Exchange Resource

Gas Chromatograph

Photograph showing an example of a typical gas chromatograph with insets showing the heated injection ports—note the symbol indicating that it is…

View Resource →
Exchange Resource

Cyclic Voltammetry

In cyclic voltammetry (CV) we scan the potential in both the cathodic and anodic directions. The illustration below shows a typical potential-excitation…

View Resource →
Exchange Resource

Pulse Polarography

Normal polarography has been replaced by various forms of pulse polarography, several examples of which are shown here. Normal pulse polarography (a),…

View Resource →
Exchange Resource

Normal Polarography

The first important voltammetric technique to be developed—polarography—uses the dropping mercury electrode as the working electrode. As shown here, the current flowing…

View Resource →
Exchange Resource

Mercury Electrodes

Three examples of mercury electrodes are illustrated here: (a) hanging mercury drop electrode, or HMDE; (b) dropping mercury electrode, or DME; and…

View Resource →
Exchange Resource

Disposable ISE

Schematic diagram of a disposable ion-selective electrode created by screen-printing. In (a) a thin film of conducting silver is printed on a…

View Resource →
Exchange Resource

Enzyme Electrode

A gas-sensing electrode can be modified to create a potentiometric electrode that respond to a biochemically important species, such as enzymes. One example…

View Resource →
Exchange Resource

pH Electrode

Schematic diagram showing a combination glass electrode for measuring pH. The indicator electrode consists of a pH-sensitive glass membrane and an internal…

View Resource →
Exchange Resource

Reference Electrodes

In a potentiometric electrochemical cell one half-cell provides a known reference potential and the potential of the other half-cell indicates the analyte’s…

View Resource →
Exchange Resource

Junction Potentials

A junction potential develops at the interface between two ionic solution if there difference in the concentration and mobility of the ions.…

View Resource →
Exchange Resource

Alizarin Garnet R

Except for a few metal ions, most notably UO2+, most inorganic ions are not sufficiently fluorescent for a direct analysis. Many metal…

View Resource →
Exchange Resource

Graphite Furnace

A typical electrothermal atomizer, also known as a graphite furnace, consists of a cylindrical graphite tube approximately 1–3 cm in length and…

View Resource →
Exchange Resource

Filter Photometer

The illustration below is a diagram of a simple filter photometer, which uses an absorption filter (shown here) or interference filter to isolate a…

View Resource →
Exchange Resource

Beer’s Law

Absorbance is the more common unit for expressing the attenuation of radiation because it is a linear function of the analyte’s concentration. When…

View Resource →
Exchange Resource

Transmittance

As light passes through a sample, its power decreases as some of it is absorbed. This attenuation of radiation is described quantitatively…

View Resource →
Exchange Resource

Atomic Spectra

The energy of ultraviolet and visible electromagnetic radiation is sufficient to cause a change in an atom’s valence electron configuration. Sodium, for…

View Resource →
Exchange Resource

Infrared Spectra

The illustration here shows two electronic energy levels (E0 and E1), each with five vibrational energy levels (ν0–ν4). Absorption of ultraviolet and visible…

View Resource →
Exchange Resource

Photomultiplier Detector

A photomultiplier contains a photosensitive surface that absorbs radiation in the ultraviolet, visible, or near IR, producing an electrical current proportional to…

View Resource →
Exchange Resource

EDTA

Structures of (a) EDTA, in its fully deprotonated form, and (b) in a six-coordinate metal–EDTA complex with a divalent metal ion.

View Resource →
Exchange Resource

Microtitrations

The illustrations below show two approaches to titrating very small samples. In the first experimental design, samples of 20–100 µL were held by…

View Resource →
Exchange Resource

Buret

A simple illustration of a typical volumetric buret. The stopcock is in the open position, allowing the titrant to flow into the…

View Resource →
Exchange Resource

Vacuum Filtration

Illustration showing the equipment for filtering a precipitate through a filtering crucible. Suction from a vacuum, often from a water aspirator, pulls…

View Resource →
Exchange Resource

Solubility of AgCl

Illustration showing the solubility of AgCl, SAgCl, as a function of pCl. The dashed red line shows SAgCl if one assumes incorrectly that the…

View Resource →
Exchange Resource

Distillation

When an analyte and interferent are miscible liquids, a separation by distillation is possible if their boiling points are significantly different. The…

View Resource →
Exchange Resource

Sample Thief

A sample thief is used for sampling smaller particulate materials, such as powders. A typical sample thief consists of two tubes that…

View Resource →
Exchange Resource

Riffle Sampler

For particulate materials, particle size often determines the sampling method. Larger particulate solids, such as ores, are sampled using a riffle, which…

View Resource →
Exchange Resource

Gravity Corer

This figure shows a schematic diagram of a gravity corer in operation. The corer’s weight is sufficient to penetrate into the sediment…

View Resource →
Exchange Resource

Penny Data Set

The data set available here contains masses for 100 circulating U. S. pennies. All pennies in these data sets were minted between…

View Resource →
Exchange Resource

pH Scale

Scale showing the pH value for representative solutions. Milk of Magnesia is a saturated solution of Mg(OH)2.

View Resource →
Exchange Resource

Matrix Effects

Sometimes the solution matrix in which the analyte resides affects the relationship between the signal and the analyte’s concentration, as shown below.…

View Resource →
Exchange Resource

Detection Limit

The figure below shows  the probability of type 1 and type 2 errors for the IUPAC detection limit. (a) The normal distribution…

View Resource →
Exchange Resource

Dixon’s Q-Test

A data point that is not consistent with the remaining data is called an outlier. Consider, for example, an experiment in which…

View Resource →
Exchange Resource

t-Test

The figure below shows the relationship between confidence intervals and the result of a t-test. (a) The shaded area under the normal…

View Resource →
Exchange Resource

Scale of Operations

Choosing an analytical methods requires a consideration of three potential limitations: the amount of sample available for the analysis, the expected concentration…

View Resource →
Exchange Resource

Precision

Two determinations of the concentration of K+ in serum, showing the effect of precision on the distribution of individual results. The data…

View Resource →
Exchange Resource

Volumetric Glassware

To measure volumes accurately and precisely, analytical chemists use volumetric pipets and volumetric flasks. A volumetric pipet is the choice when needing…

View Resource →
Exchange Resource

p-Function

When the concentration of a species spans many orders of magnitude, it is difficulty to display how that species’ concentration changes during…

View Resource →
Exchange Resource

GC Columns

The photo below shows a typical example of a packed column for gas chromatography. This column is made from stainless steel and…

View Resource →
Exchange Resource

GC Detectors

Shown below is a schematic diagram of a thermal conductivity detector. This is one of a matched pair of cells. The sample…

View Resource →
Exchange Resource

GC Injectors

Shown below is a schematic diagram of a heated GC injector port for use with a packed column. The needle pierces a…

View Resource →
Exchange Resource

Sampling M & Ms

Carry out the following “experiment” to test the validity of the sampling constant equation mR2 = Ks where m is the sample’s…

View Resource →
Exchange Resource

Concentrations

Gratzel et. al. [Anal. Chem. 1999, 71, 2751-2756] describe the use of a diffusional microburet to transfer solutions to very small droplets…

View Resource →
Collection Resource

Uncertainty Calculator

This site contains a JavaScript “Uncertainty calculator,” which determines the uncertainty of a calculated result given the uncertainties for the measurements. The…

View Resource →

Showing 12 of 284 resources